Appearance and Structure

|
1 |
Twenty-four 10GE SFP+ ports Applicable modules and cables:
|
2 |
Six 40GE/100GE QSFP28 optical ports Applicable modules and cables:
NOTE:
A QSFP28 optical port cannot be split into four 10GE ports, regardless of whether the port uses a QSFP28 or QSFP+ optical module. For the S6730-H24X6C (part number: 02352FSG/02352FSG-001/02352FSG-005):
For the S6730-H24X6C (part number: 02353GFC/02353GFC-001/02353GFC-003), the license has been activated and QSFP28 ports on the switch work as 100GE ports. To change the rate of QSFP28 ports from 100GE to 40GE, run the undo assign port-speed 100GE command and restart the switch (undo assign port-type 100GE command in V200R020C00 and later versions). |
|
3 |
Ground screw NOTE:
It is used with a ground cable.
|
4 |
SSD card slot NOTE:
This slot is reserved for future use. |
|
5 |
One console port |
6 |
One ETH management port |
|
7 |
One USB port |
8 |
One PNP button NOTICE:
To restore the factory settings and reset the switch, hold down the button for at least 6 seconds. To reset the switch, press the button. Resetting the switch will cause service interruption. Exercise caution when you press the PNP button. |
|
9 |
Fan module slot 1 NOTE:
Applicable fan module: FAN-031A-B (Fan box(B,FAN panel side exhaust)) |
10 |
Fan module slot 2 NOTE:
Applicable fan module: FAN-031A-B (Fan box(B,FAN panel side exhaust)) |
|
11 |
Fan module slot 3 NOTE:
Applicable fan module: FAN-031A-B (Fan box(B,FAN panel side exhaust)) |
12 |
Fan module slot 4 NOTE:
Applicable fan module: FAN-031A-B (Fan box(B,FAN panel side exhaust)) |
|
13 |
Power module slot 1 NOTE:
Applicable power module:
|
14 |
Power module slot 2 NOTE:
Applicable power module:
|
Port Description
10GE SFP+ optical port
40GE/100GE QSFP28 optical port
Console port
ETH management port
|
Attribute |
Description |
|---|---|
|
Connector type |
RJ45 |
|
Standards compliance |
IEEE802.3 |
|
Working Mode |
10/100 Mbit/s auto-sensing |
|
Maximum transmission distance |
100 m |
In V200R012C00 and later versions, you can log in to the switch that contains the ETH management port for the first time through the ETH port. For details, see “First Login to a Switch” in the Configuration Guide – Basic Configuration. If you have logged in to the switch for the first time by pressing and holding the MODE button for 6 seconds or longer and saved the configuration, the default configuration on the ETH port will be cleared. In this case, you cannot log in to the switch for the first time through the ETH port. You are advised to log in to the switch for the first time through the ETH port.
USB port
USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.
Indicator Description
The S6730-H24X6C has the same types of indicators as the S6730-H48X6C. For details, see Indicator Description.
Power Supply Configuration
The switch can use a single power module or double power modules for 1+1 power redundancy. Pluggable AC and DC power modules can be used together in the same switch.
Heat Dissipation
The S6730-H24X6C uses pluggable fan modules for forced air cooling. Air flows in from the front side and exhausts from the rear panel.